Texas bills would end the data center sales tax exemption, which we estimate adds ~3-4 USD/MWh to their power bills, yet 15-yr ERCOT solar Fair Values held near 41 USD/MWh.
Texas lawmakers have started to write the rules for the data center boom. On 9 November, the first day of bill filing for the 2027 session, Senator Joan Huffman and other senators filed Senate Bill 293, which would repeal the state sales and use tax exemptions for qualifying data centers and large data center projects. Exemptions already granted would expire when the law takes effect, and pending applications would be denied. A similar House bill, HB 681, would let certified data centers keep their exemption until it runs out.
Senator Judith Zaffirini filed Senate Bill 32 (SB 32), which would require a permit from the Public Utility Commission of Texas (PUCT) before construction of any computing site of 75 MW or more starts, from 1 September 2027. The bills arrive as Governor-elect Gina Hinojosa, who takes office in January, campaigned on a moratorium on data center approvals until new laws pass. The session convenes on 12 January.
We estimate that ending the exemption on electricity alone would add the 6.25% state sales tax to a data center’s power bill, about 3-4 USD/MWh on supply costs of 50-60 USD/MWh, before local taxes (1). Equipment carries the larger cost: a USD 1 billion purchase of servers and cooling equipment would owe about USD 62.5 million. In July, the Texas Comptroller’s office told senators that the exemption would cost the state about USD 3.3 billion in 2028-2029.

In July, ERCOT told the Senate that about 474 GW of large loads were seeking to connect, about 90% of them data centers. Its Batch Zero review has since kept 66.4 GW in the base case, put 127.9 GW into the study group, and excluded 302.2 GW, with a report to the PUCT due on 10 December. Data center buyers also carry ERCOT’s offtake market, as hyperscalers signed about 3,060 MW, or 59%, of the 5,169 MWac of ERCOT offtake deals announced this year (3).
For batteries, slower data center growth would weigh on evening scarcity, which sets the top of the daily price spread. Every 1 USD/MWh taken off that spread is worth ~0.06 USD/kW-month to a 2-hour battery (4). Pexapark’s ERCOT Composite 7-yr TB2 (top-bottom 2-hour) Fair Value was 5.86 USD/kW-month on 13 November (2)(4). Toll sellers who price tighter evenings later in the decade carry the most exposure to a permit regime that slows new load from 2027.
We expect long-tenor ERCOT values to stay near 40 USD/MWh until the session clarifies which projects keep their exemption, because the bills mainly hit new projects and ERCOT’s base case already excludes most requests. If both the tax repeal and the PUCT permit pass, the risk falls first on 15-yr values and on toll offers that rely on load growth after 2030.
Buyers should ask sellers how offers treat a slower-load case after 2030 and seek change-in-law terms for Texas tax and permit changes. Developers and independent power producers (IPPs) with data center offtakers should check whether the buyer’s site is already certified and when it is due to energize.
Notes
(1) Illustrative estimate, energy only: the 6.25% state sales tax applied to an all-in electricity supply cost of 50-60 USD/MWh gives 3.1-3.8 USD/MWh; local sales taxes of up to 2% would add more. Equipment: 6.25% x USD 1 billion = USD 62.5 million. SB 293 and HB 681 also remove data centers from the Tax Code 151.317 exemption for gas and electricity.
(2) Pexapark Fair Values (Quant API, internal), valuation dates 6 and 13 November 2026 (13 November is the latest valuation available on 16 November). Solar: ERCOT North 10-yr and 15-yr, start 1 January 2028, as-generated, including RECs. TB2: ERCOT Composite, 7-yr, start 1 January 2028, Perfect including capacity (Perfect = average top minus average bottom minus round-trip efficiency loss, before the persistence discount; capacity is zero in ERCOT), USD/kW-month.
(3) Pexapark’s PPA Tracker, publicly announced or disclosed US offtake deals tracked as of 3 November 2026 (deals announced 1 January to 6 November 2026, excluding terminated contracts and pre-2026 contracts now delivering); not a complete market total.
(4) TB2 = top-bottom fixed-price financial agreement on the maximum theoretical daily Day-ahead spread for a 2-hour battery, one cycle, perfect foresight, with no degradation, round-trip efficiency, intra-day or ancillary revenue. 1 USD/MWh x 2 h x 365 / 12 / 1,000 = ~0.06 USD/kW-month.